Backup power design: UPS and standby generators
Guaranteed and emergency power — UPS, rotary UPS and standby generators — for buildings that cannot switch off. From the power balance to blackout tests.
Scope
What the design covers
- Critical load power balance and resilience class (N+1, 2N, Tier)
- Static UPS and rotary UPS (DRUPS): rating, autonomy and configuration
- Standby generators: sizing, single or parallel operation, location and coordination with other trades (fuel, ventilation, exhaust)
- Automatic transfer switching between mains and generator
- Guaranteed-power switchboards, A/B paths, protection selectivity
- Power for server rooms, fire and voice alarm panels, medical and airport equipment
- UPS and generator monitoring in the BMS
- Fire safety expert approval and designer's site supervision
Why Eko Elprom
What the client gains
ICM, University of Warsaw: 15 kV supply rated at 4 MW and two 1600 kW rotary UPS units (2013–2014).
Asseco data processing centre in Kraków: 1.4 and 1.8 MVA generators, 2 MVA UPS in two chains, 176 racks.
Cape of Hope clinic: 630 kVA generator with 24-hour autonomy, 160 kVA UPS for medical equipment.
Hutchinson hall: generators totalling 2600 kVA; Radom air traffic control tower: 900 kVA generator, 4 × 75 kVA UPS.
Process
From first sketch to handover
One lead designer at every stage. Cross-discipline coordination, approvals with distribution system operators and utilities, presence on site.
Load balance and resilience
Critical loads, required autonomy, choice of N, N+1 or 2N.
Choice of sources
Static or rotary UPS, generator rating and location, fuel tank, transfer switching.
Detailed design
Switchboard and power path diagrams, selectivity, routes, controls and BMS signals.
Tests and acceptance
Designer's supervision, support for blackout tests and acceptance.
Projects with backup power
Photos: our archive and partner materials — credits in the descriptions. See all projects →






FAQ
Client questions
Answers to the questions we hear most often when quoting this type of project.
Contact
Free quote: backup power design
Send drawings, a brief or a short scope description — we will reply within one working day and send a quote with a schedule within two working days.