Server rooms and data centres
Data centre and server room design — multidisciplinary, in one team
From the power balance and redundancy class to a coordinated detailed design across all disciplines. One lead designer, single-point responsibility, documentation ready for tender.
Scope
What the design covers
- Uninterruptible power supply: static UPS and ROTARY UPS, generator sets, automatic transfer switching (ATS), N+1 / 2N redundancy
- MV/LV power distribution, main and zonal switchboards, busbar trunking, cable routes
- Server room cooling and HVAC, cold/hot aisles, free cooling — in cooperation with the plumbing & HVAC discipline
- BMS / DCIM automation, monitoring of environmental and power parameters
- Fire alarm system (FAS), early smoke detection, fixed gas fire suppression systems
- Access control, CCTV, intruder and hold-up alarm system (I&HAS), structured and fibre-optic cabling
- Cross-discipline coordination, approvals with the distribution system operator, certified experts and the operator
- Designer's site supervision, acceptance inspections, as-built documentation
Why Eko Elprom
What the client gains
All server room disciplines in one team — no demarcation disputes between designers on site.
Server rooms for MON, a bank, the Polish Embassy in New Delhi, ICM UW (University of Warsaw; the first ROTARY UPS in Poland) and Samsung — we have designed under the security regimes required by state and financial institutions.
Schematics, schedules and bills of quantities prepared so that the contractor can price and build reliably.
We handle correspondence with the distribution system operator, network operators and experts in parallel with the design — the client doesn't wait on formalities.
Process
From first sketch to handover
One lead designer at every stage. Cross-discipline coordination, approvals with distribution system operators and utilities, presence on site.
Concept and power balance
Needs analysis, power balance, selection of primary and standby power sources, grid connection conditions.
Building permit design
Documentation for the building permit, approvals with the distribution system operator, utilities and certified experts.
Detailed design
Schematics, layouts, calculations, material schedules and bills of quantities — ready for tender and construction.
Designer's site supervision
Contractor support, site changes, acceptance and as-built documentation.
Projects
Selected projects in this field
Photos from our project archive. See all projects →





FAQ
Client questions
Answers to the questions we hear most often when quoting this type of project.
Contact
Free quote: server rooms and data centres
Send drawings, a brief or a short scope description — we will reply with a quote and a schedule within one working day.
Address
ul. Myśliwska 66/123, 30-718 Kraków, Poland
Office
Electrical department
ELV department
Telecommunications design
+48 533 317 286
HVAC automation & BMS
+48 507 874 718